Zobrazit stránku 19
PAGE 20 — MVC-90H PLATE COMPACTOR — OPERATION AND PARTS MANUAL — REV. #3 (01/10/11)
l
MVC-90H PLATE COMPACTOR — SHUT-DOWN PROCEDURE
NEVER stop the engine suddenly while working at high
speeds. This can damage your engine.
1. Place the
throttle lever
(Figure 15) in SLOW position,
and listen for the engine speed to decrease.
Stopping the Engine
Figure 15. Throttle Lever (SLOW Position)
2. Place the
Engine ON/OFF switch
(Figure 16) in the OFF
position.
Figure 16. Engine ON/Off Switch (OFF Position)
3. Place the
fuel valve lever
(Figure 17) in the OFF
position.
Figure 17. Fuel Valve Lever (OFF Position)
CAUTION - Stopping the engine while working
Emergency Shutdown Proucedure:
1. Move the throttle lever quickly to the SLOW
position
(Figure 15).
2. Place the engine ON/OFF switch in the OFF position
(Figure 16).